HOMETechnical DataValve of Pumping system |
|
|
This check valve protects the pump by bypassing the discharge pressure that instantaneously rises when the pump starts. It also absorbs shock by linearly opening the water hammer cushion valve to prevent a water hammer resulting from a surge in pressure by the backward flow of water inside a standing pipeline when the pump stops. In addition, this product has a port soft sealing structure, thereby ensuring perfect air tightness at normal times. |
|
- Outlet-side water pressure < Spring force
- he auxiliary valve opens
- Water from the main valve passes through points D, E, and F, and flows in the direction of point G
- Water at A, the upper part of the main valve diaphragm, flows in the direction of point D(If only a small amount of water is used or is not used at all on the inlet side)
- Volume of water that was filled up at A goes down
|
|
Type |
Ycc-1, 1R |
Ycc-2, 2R |
Ycc-3, 3R |
Applicable fluid |
|
Water,Liquid |
|
Applicable Pressure |
Maximum 10kgf/cm g |
Maximum 20kgf/cm g |
Maximum 30kgf/cm g |
Fluid temperature |
Maximum 80¢ª C |
Maximum 120¢ª C |
Maximum 120¢ª C |
End connection |
KS 10K FF FLANGED |
KS 20K RF FLANGED |
KS 30K RF FLANGED |
Hydraulic test pressure |
15kg f/cm |
30kg f/cm |
45kg f/cm |
Materials |
BODY |
GC200 |
GCD450 |
SCP H2 |
Seat |
|
BC6 |
|
Disc |
|
EPDM |
|
Gasket |
NBR,EPDM |
NBR, EPDM |
NBR, EPDM |
|
|
|
|
- Structure to verify whether internal screen need cleaning.
- Quick-changeable hinge structure enable quick cleaning of the screen.
- Built-in magnet protects the pump & pipeline from damage caused by iron content & welding slags.
- Maximized pump efficiency & little pressure loss by outlet side located vane.
|
|
|
|
|
|